How to Check a UK New Build Meets Fire Regulations: Approved Document B Explained
· 4 min read · By Verify AI
To check a UK new build meets fire regulations, start with Approved Document B (Fire safety) for England, work through the topics it covers, and keep evidence that the design and installed systems meet it. Approved Document B is statutory guidance for the Building Regulations. Following it is the usual way to show compliance, and other routes, such as British Standards or fire engineering, are accepted if you can demonstrate they meet the requirements.
This guide covers England. Scotland, Wales and Northern Ireland have their own regulations and guidance.
Which volume applies
- Volume 1 covers dwellings.
- Volume 2 covers buildings other than dwellings.
The 2019 edition, incorporating the 2020 and 2022 amendments, is the current reference per the Planning Portal. The 2020 amendments included reducing the sprinkler trigger height for dwellings from 30 m to 11 m. Further amendments were published on 29 March 2024, with commencement and transitional dates that depend on when a building notice or initial notice was given. Check the government circular for the date that applies to your project.
What to check
Approved Document B is organised around functional requirements. Use them as a review structure:
| Topic | What to verify in the design |
|---|---|
| Means of warning and escape | Alarm and detection, escape routes, travel distance, stair provision |
| Internal fire spread (linings) | Surface spread of flame classes for wall and ceiling linings |
| Internal fire spread (structure) | Fire resistance of structure, compartmentation, cavity barriers, protection of openings and fire-stopping |
| External fire spread | Wall construction and materials, boundary distance, roof coverings |
| Access and facilities for the fire service | Vehicle access, firefighting shafts and water supplies where needed |
Where BS 9999 fits
BS 9999:2017 is a British Standard code of practice for fire safety in the design, management and use of buildings. It is a recognised alternative source of guidance to Approved Document B for some buildings, often used where a more flexible, risk-based approach is wanted. Confirm with your building control body which route they accept.
Higher-risk buildings and the Building Safety Regulator
The Building Safety Act 2022 created the Building Safety Regulator within the Health and Safety Executive. It has responsibility for the review of Approved Document B guidance and, for higher-risk buildings, additional approval stages. If your building falls in that category, check the Regulator's current guidance for the process that applies. We have not set out the stage details here because they change.
A practical pre-submission check
- Confirm the route. Approved Document B, BS 9999, or fire engineering, agreed with building control.
- Record the edition and amendments and the transitional date that applies to your project.
- Check escape. Travel distances along the walking path, stair widths and numbers, alarm and detection.
- Check compartmentation. Fire-resisting walls and floors continuous, penetrations and cavity barriers protected.
- Check external walls and materials. Details against the current rules on materials.
- Check fire service access and firefighting provisions.
- Keep the evidence: product certification, test reports and commissioning records.
Frequently asked questions
Is Approved Document B mandatory?
It is guidance. Following it is the usual way to show you meet the Building Regulations, but you can show compliance another way.
What is the difference between Volume 1 and Volume 2?
Volume 1 covers dwellings. Volume 2 covers other buildings.
Is BS 9999 an alternative?
It is a recognised code of practice that can be used as an alternative source of guidance, subject to agreement with building control.
Do the recent amendments apply to my project?
Transitional rules depend on when a notice was given. Check the government circular on the amendments.
Pre-check a UK design
Verify AI references UK requirements including Approved Document B and BS 9999 and reports the clause behind each finding. See Verify AI for the UK, or talk to the founder.
Sources
- Approved Document B: Fire safety, Planning Portal
- Amendments to Approved Document B, UK Government circular
- Approved Document B, Designing Buildings
General information as of November 2026, not legal advice. Confirm current requirements and transitional arrangements with building control.