Pass Fire NOC & NBC review on your first submission.
Audit your drawings and BIM models against NBC 2016 Part 4, the newly notified NBCS 2026 (SP 7:2026 Part F), and state Fire Service bylaws — before you submit to Invest Punjab, MIDC, DFS, or KSFES.
Codes and standards in India
- National Building Construction Standards 2026 (NBCS 2026 / SP 7:2026) (Bureau of Indian Standards (BIS)): Part F: Fire & Life Safety, 24 m high-rise threshold, performance-based egress, and modern EV sprinkler mandates.
- National Building Code of India 2016 (NBC 2016 Part 4) (Bureau of Indian Standards (BIS)): Fire & Life Safety: occupant load calculation, travel distance, staircase capacity, and fire tender road clearances.
- State Fire Service Acts & Municipal Building Bylaws (State Fire Services & Municipal Authorities): State-specific adoption of fire norms across Punjab, Maharashtra (MIDC/MCGM), Karnataka (BBMP/KSFES), Delhi (DFS), and Telangana.
- IS 12458:2019 & Fire Penetration Standards (BIS): Fire-stop materials, tested fire door assemblies, and MEP service penetration integrity across compartment walls.
How Fire NOC & Plan Approval works in India
Securing building approvals and an Occupancy Certificate (OC) requires clearance from both the local planning authority and State Fire Services.
- Provisional Fire NOC (Design Stage): Drawings are reviewed for means of egress, staircase widths, travel distances, refuge areas, and fire tender pathways before building permit issuance.
- Building Plan Sanction: The municipal body or development authority sanctions the architectural and structural plans conditional upon provisional fire clearance.
- Installation & Inspection: Active firefighting systems (sprinklers, hydrants, alarms, pumps, and fire lifts) are installed and tested on site by licensed agencies.
- Final Fire NOC & Occupancy Certificate (OC): State Fire Services conduct an on-site joint inspection. Once verified, the Final Fire NOC is issued with a verifiable QR code, enabling the Occupancy Certificate.
What Verify AI checks
- Travel distance & dead-end corridors (shortest walking path) — NBC 2016 Part 4 / NBCS 2026 Part F
- Staircase width, riser/tread geometry, and occupant load — NBC 2016 Cl. 4.4 / NBCS 2026
- Refuge area sizing and protected fire tower provisions — NBC 2016 Part 4 Cl. 4.6
- Fire tender access road width (min 6 m) and turning radius — NBC 2016 Part 4 Cl. 4.2
- Fire door rating validation and compartmentation boundaries — NBC 2016 Cl. 4.3 / IS 12458:2019
- Fire damper placement at compartment wall penetrations — NBC 2016 Part 8 / NBCS 2026
- DG room and transformer separation clearances — NBC Part 8 Section 2 / CEA Regulations
- Sprinkler, wet riser, and yard hydrant hydraulic layout — NBC 2016 Part 4 Table 7
Frequently asked questions
Does Verify AI check drawings against NBC 2016 or the new NBC 2026?
Verify AI supports both NBC 2016 Part 4 and the newly notified NBCS 2026 (SP 7:2026 Part F). You can select your applicable code version depending on whether your state authority has updated its local building bylaws.
Which state fire portals and rules are supported for Fire NOC pre-checks?
Verify AI validates drawing requirements compatible with state single-window systems including Invest Punjab (Business First), Maharashtra Fire Gateway, Karnataka KSFES, Delhi Fire Service (DFS), and Telangana TS-bPASS.
What drawing formats can I upload for checking?
You can upload openBIM IFC files (IFC 2x3 and IFC4), AutoCAD DWG / DXF floor plans, and vectorized PDF drawing sets.
How does Verify AI measure travel distance?
Unlike manual diagonal estimates, Verify AI calculates actual walking routes around walls, partitions, and fixed corridors to ensure strict compliance with NBC travel distance and dead-end limits.