Fire door rating validation in your BIM model.

Fire door rating validation in BIM checks that every door on an exit route carries a FireRating that matches the wall it sits in. See the IFC properties read and the common failures.

What is fire door rating validation?

Fire door rating validation checks every door that matters for fire safety: that it has a fire rating recorded, that the rating is at least what the code requires for where the door is, and that it matches the wall around it. Unverified door ratings are among the most common comments on fire submissions, and in a BIM model they are easy to catch because the rating is a property on the door.

What the code asks for

The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.

How it shows up in an IFC model

InformationIFC locationWhat a check reads
Fire ratingPset_DoorCommon.FireRating on IfcDoorRating recorded for the door assembly, compared with the requirement
Fire exit flagPset_DoorCommon.FireExitWhether the door serves as an exit in a fire
Self-closingPset_DoorCommon.SelfClosingWhether the door closes by itself
Smoke stopPset_DoorCommon.SmokeStopWhether the door is designed to resist smoke
Host wall ratingPset_WallCommon.FireRating on the wall the door fillsDoor rating compared with the wall rating

Why models fail this check

What a Verify AI finding looks like

Example finding: door rating below requirement

Severity: HIGH

Element: IfcDoor "Door_Stair_02_L1"

Location: Level 1, Staircase 2 access corridor

Detected: FireRating = "30 min"

Requirement: higher-rated assembly for a protected stair enclosure, per the edition in force

Action: change to the required rated assembly with self-closing device and seals

This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.

How to prepare your model

  1. Use the standard property: record the rating in Pset_DoorCommon.FireRating, not in a custom parameter.
  2. Pick one format: choose a single format for ratings (for example minutes) across all models.
  3. Fill every rated door: include doors to stairs, lift lobbies, shafts and compartment walls.
  4. Match the wall: confirm door and host wall ratings agree.
  5. Reconcile the schedule: compare the model with the door schedule before submission.

Frequently asked questions

Where is the fire rating stored in an IFC model?

In the standard property set Pset_DoorCommon, property FireRating, on the IfcDoor (or its type). The value is a text label, which is why a single consistent format matters.

What rating does a stair enclosure door need?

It depends on the code edition and authority. The check compares the recorded rating with the requirement in the edition you select and cites the clause. Do not assume a single number applies everywhere.

Can the check tell if a door is a certified assembly?

It can check that a rating is recorded and consistent. Certification of the physical assembly comes from the manufacturer's test evidence, which your team attaches to the submission.