BIM fire compliance checking, before you submit.

Check an IFC model against fire and life safety rules, and get each finding pinned to the plan with the clause it was checked against. This guide covers what is checked, how it works and how to prepare your model.

What is BIM fire compliance checking?

BIM fire compliance checking is an automated review of a building model against fire and life safety requirements. Because an IFC model describes what each object is (a door, a wall, a stair) and its properties (such as fire rating), a rule engine can test it directly, instead of a person reading drawing sheets one at a time.

It does not replace a fire consultant. It makes the review shorter by finding mechanical, repeatable issues first, so people spend their time on judgement calls. Read our walkthrough: how to check an IFC model for building code compliance.

What gets checked

CheckWhat it findsGuide
Model healthUnbounded spaces, proxies, storeys, units, missing propertiesIFC model health check
ClassificationElements that cannot be recognised by rulesIFC classification checking
Fire doorsMissing or low ratings, mismatch with the wallFire door rating validation
CompartmentationGaps in fire walls, shafts not enclosedFire wall continuity
PenetrationsDucts and pipes through rated walls with no damper or fire-stopService penetrations
EgressWalking-path distance, dead endsTravel distance
ClearancesBlocked exits, panel space, door swingsClearance zones
Smoke controlStair pressurisation fans, ducts, reliefStair pressurisation
Emergency power and lightingEscape route lighting and supplyEmergency lighting
SuppressionSprinkler coverage, spacing, obstructionsSprinkler coverage

How it works

  1. Upload your model or drawings: Drag and drop a coordinated IFC (IFC2x3 or IFC4) or a Revit-exported model. DXF and PDF drawings are supported too.
  2. Fire and MEP systems are detected: Fire zones, doors, stairs, sprinklers, ducts, panels and plumbing networks are identified across the model.
  3. Rules are applied for your jurisdiction: Checks run against the framework you select (for example NBC / NBCS, NFPA, UAE Fire Code, SBC 801, SCDF, BS 9999), with the edition and clause recorded for each finding.
  4. You get a report with overlays: Findings are pinned to the plan, ranked by priority, with suggested fixes, so the team can resolve and re-check.

A workflow that works on real projects

What automated checking cannot do

Frequently asked questions

What is BIM fire compliance checking?

Automated testing of a building model against fire and life safety rules, using the object types and properties in an IFC file, so issues are found before submission.

Which IFC versions does Verify AI read?

IFC2x3 and IFC4, including coordinated models exported from Revit. Verify AI also reads DXF and PDF drawings.

Does it work for Indian, UAE and UK codes?

Verify AI is jurisdiction-aware and references frameworks such as NBC and NBCS 2026, NFPA, the UAE Fire Code, SBC 801, SCDF and BS 9999, with the edition recorded in each finding.

Will it replace my fire consultant?

No. It finds repeatable issues quickly so the consultant's time goes to judgement. A qualified person still reviews and signs the submission.

How do I prepare a model?

Start with a model health check: bound spaces, classify elements, set storeys, check units and export common property sets. The IFC validation matrix is a one-page checklist.

Related

Sources

Try Verify AI · See a sample report · Talk to the founder