Travel distance checking, along the real walking path.
Travel distance checking measures the walking path from the farthest point in a space to the nearest exit, not the straight line. See how it works in an IFC model and why straight-line checks fail.
What is travel distance checking?
Travel distance is how far a person has to walk from a point in a building to reach an exit. Fire codes limit it, and reviewers measure it along the walking path, around walls, furniture and partitions, not as a straight line. Checking it by hand on every floor is slow. A model-based check finds the farthest point in each space, builds the walking route through doors and corridors, and compares it to the limit.
What the code asks for
- Maximum travel distance depends on the occupancy, the edition of the code, and whether the building is sprinklered. The limit always comes from the code the authority applies.
- Distance is measured along the actual path of travel, through doors and around obstructions.
- Dead-end corridors must stay within the permitted length.
- Two or more exits are required where occupancy or distance calls for them.
The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.
How it shows up in an IFC model
| Item | IFC entity | What a check reads |
|---|---|---|
| Spaces and their usage | IfcSpace | Start points (farthest point in each room) and occupancy |
| Doors and openings | IfcDoor | Where the path passes from one space to the next |
| Stairs and final exits | IfcStair, exit doors | The destination of the path |
| Walls and obstructions | IfcWall, furnishings | What the path has to go around |
Why models fail this check
- Measuring in a straight line, which understates the real distance.
- Unbounded spaces, so the path has no valid start or finish.
- Doors missing from the model, so spaces look unconnected or connected through a wall.
- Using the wrong occupancy for a space, which applies the wrong limit.
- Applying a sprinklered limit where the sprinkler system is not confirmed.
What a Verify AI finding looks like
Example finding: travel distance over limit
Severity: HIGH
Element: IfcSpace "Open office"
Location: Level 6, far corner from Stair 1
Detected: walking-path distance is over the limit for the space's occupancy
Action: add an exit, relocate partitions, or provide a second means of egress
This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.
How to prepare your model
- Bound every space: close rooms so each has a start point.
- Model all doors: include every door and opening on the route.
- Set occupancy: record the use of each room.
- Confirm sprinklers: state whether the area is sprinklered.
- Read the path: review the route the check produced, not just the number.
Frequently asked questions
Why is straight-line distance wrong?
People cannot walk through walls. Reviewers measure along the path they would actually take, which is always as long or longer than the straight line.
What is the maximum travel distance?
There is no single answer. It depends on the occupancy, the code edition, and sprinkler protection. Always use the figure in the code your authority applies.
What is a dead end?
A corridor or space from which there is only one way out. Codes limit how long a dead end may be.