IFC model health check, the step before compliance.

An IFC model health check finds the export problems that stop code rules from running: unbounded spaces, proxies, wrong storeys and unit errors. Use this checklist before any compliance check.

What is ifc model health check?

An IFC model health check tests the model itself rather than the building: are spaces properly bounded, are elements classified and on the right storey, are units consistent, are required properties present. Compliance rules rely on all of that. A model with unbounded spaces or a unit error will not just produce poor results, it can produce confident wrong ones, so health comes first.

What the code asks for

The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.

How it shows up in an IFC model

Health itemWhere it livesWhy it matters
Bounded spacesIfcSpace and its boundariesOccupant load, travel distance and egress simulations fail on unbounded spaces
No critical proxiesIfcBuildingElementProxyRules cannot apply to elements that are not recognised
Storey assignmentIfcBuildingStorey containmentVertical rules (stairs, shafts, compartmentation) need the correct level
Units and scaleIfcProject unitsA 1,000x error corrupts every distance and width check
Required propertiesPset_DoorCommon, Pset_WallCommon and othersRatings and flags cannot be read if the property sets are not exported
DuplicatesOverlapping elementsDouble-counted walls or doors cause false findings

Why models fail this check

What a Verify AI finding looks like

Example finding: unbounded space

Severity: MEDIUM

Element: IfcSpace "Open office"

Location: Level 6

Detected: space boundary not closed along the east edge

Impact: occupant load and travel distance cannot be calculated reliably

Action: close the room boundary with a wall or room-separation line and re-export

This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.

How to prepare your model

  1. Close the rooms: add room-separation lines where a space is open to another.
  2. Replace proxies: map or remodel generic objects that matter for fire.
  3. Check storeys: confirm every architectural and MEP element sits on the right level.
  4. Confirm units: check the project units in the export and in the receiving tool.
  5. Export the properties: turn on common property sets in the export settings.

Frequently asked questions

What is an IFC model health check?

A test of the quality of an IFC file, separate from code compliance: whether spaces are bounded, elements classified, storeys correct, units consistent and properties present.

Why run it before compliance checks?

Rules assume a sound model. If the model has structural problems, results are unreliable. Fixing health first means the compliance report shows real design issues.

Which IFC versions are supported?

Verify AI reads IFC2x3 and IFC4 models, including coordinated models exported from Revit, and drawings in DXF or PDF.

Related

Sources

Try Verify AI · See a sample report · Talk to the founder