Emergency lighting check along every escape route.
Emergency lighting checking confirms escape routes, stairs and exits have emergency fixtures on an emergency circuit, so egress illumination gaps are found before the site does.
What is emergency lighting check?
Emergency lighting checking confirms that corridors, stairs and exits have fixtures that stay on when normal power fails. The check follows each escape route in the model and looks for gaps in fixture coverage and for fixtures that are not connected to an emergency supply. Illumination levels are then assessed against the standard the project uses.
What the code asks for
- Escape routes, stairs, exits and changes of direction have emergency or exit lighting.
- Fixtures serving escape routes are connected to an emergency circuit or a self-contained battery supply.
- Illumination along the route meets the level in the applicable standard (for example the local fire code or the electrical standard the project follows).
- Exit signs are present and visible at exits.
The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.
How it shows up in an IFC model
| Item | IFC entity | What a check reads |
|---|---|---|
| Escape route | IfcSpace, IfcDoor, IfcStair | The route that needs lighting |
| Fixture | IfcLightFixture | Position of emergency or exit fixtures |
| Circuit | IfcElectricDistributionBoard and circuit data | Whether the fixture is on an emergency supply |
| Exit signs | IfcLightFixture or sign objects | Signs at exits |
Why models fail this check
- Fixtures modelled but not tagged as emergency, so the check cannot count them.
- Gaps in coverage in corridors, at stair landings or at turns.
- No circuit assigned, so the supply type is unknown.
- Lighting layout only in a separate lighting calculation, not in the model.
- Exit signs missing at secondary exits.
What a Verify AI finding looks like
Example finding: no emergency lighting on route
Severity: MEDIUM
Element: IfcSpace "Corridor"
Location: Level 9, east escape route
Detected: no emergency fixtures assigned along the route
Action: add fixtures on the emergency circuit and tag them
This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.
How to prepare your model
- Tag the emergency fixtures: use a consistent property for emergency and exit lights.
- Assign circuits: record which circuit or battery serves each fixture.
- Cover the whole route: check corridors, landings and turns.
- Add signs: include exit signs at every exit.
- Keep the calculation: attach the illumination calculation to the submission.
Frequently asked questions
What is emergency lighting?
Lighting that switches on automatically when the normal supply fails, so people can find their way out.
Can a model check light levels?
A model can check that fixtures exist, where they are and what supply they are on. Light levels are normally confirmed by a lighting calculation, which the check can reference.
Which standard applies?
It depends on the country and project. Verify AI references standards such as SBC 801 in Saudi Arabia where it applies, and the local code elsewhere.
Related
- BIM fire compliance checking: the complete guide
- Clearance zone checking
- Travel distance
- Stair pressurisation
- How to check an IFC model for building code compliance