Stair pressurisation checking between architecture and HVAC.

Stair pressurisation checking confirms enclosed stairs have fans, supply routes and relief paths modelled, so smoke is kept out of the escape route. See what is checked in a BIM model.

What is stair pressurisation checking?

Stair pressurisation keeps smoke out of an escape stair by supplying air so the stair stays at a higher pressure than the rest of the building. It only works if the architectural stair, the fan, the supply duct and the air relief path are all present and connected. Checking that across two disciplines is the kind of cross-model task an automated check handles well.

What the code asks for

The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.

How it shows up in an IFC model

ItemIFC entityWhat a check reads
Enclosed stairIfcStair, IfcSpace for the enclosureWhich stairs are protected enclosures
Pressurisation fanIfcFanPresence and location of the fan
Supply ductIfcFlowSegment, IfcDuctSegmentWhether the fan is connected to the stair
Relief pathIfcDamper, IfcAirTerminal, openingsWhere air can leave the building floors
Stair doorsIfcDoorDoor properties and rating at the enclosure

Why models fail this check

What a Verify AI finding looks like

Example finding: stair has no supply route

Severity: HIGH

Element: IfcStair "Stair 2"

Location: Levels B1 to 14

Detected: no pressurisation fan connected to the enclosure

Impact: stair may not be protected against smoke

Action: confirm the design basis and model the fan, duct and relief path

This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.

How to prepare your model

  1. Name stairs consistently: use the same identifiers in every model.
  2. Model the whole system: fan, duct, outlets and relief.
  3. Connect the system: check the duct reaches the stair.
  4. Check power: confirm the fan is on the emergency supply.
  5. Agree the standard: state which smoke control standard the design uses.

Frequently asked questions

What does a stair pressurisation system do?

It supplies air to an escape stair so that, if there is a fire elsewhere, smoke is pushed out of the stair and people can use it safely.

Do all stairs need it?

No. Whether a stair needs pressurisation depends on the building height, use and the code. The check applies the rule from the edition you select.

Why check it in the model?

Because it spans two disciplines. A stair on the architect's drawings and a fan on the engineer's are easy to leave unconnected until late in a project.