Service penetrations and fire-stopping, found before the site does.
Check ducts, pipes and cable trays that cross fire-rated walls and floors in your BIM model: missing fire dampers, unsealed openings and fire-stop requirements such as IS 12458:2019.
What is service penetration fire-stopping check?
A service penetration check finds every place a duct, pipe or cable tray crosses a fire-rated wall or floor, and confirms the opening is protected: a fire damper in a duct, a tested fire-stop around a pipe or tray. These are the places fire and smoke spread between compartments, and they sit exactly where the architectural and MEP models meet, which is why they are easy to miss.
What the code asks for
- Where a duct passes through a rated wall or floor, a fire damper (or an equivalent tested solution) is expected at the boundary.
- Pipes, cables and trays through rated elements need tested fire-stop systems. NBCS 2026 calls for fire-stop systems certified to IS 12458:2019.
- Openings in rated elements are sized to suit the tested system.
- Penetrations are coordinated so the fire-stop contractor has information to work from.
The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.
How it shows up in an IFC model
| Item | IFC entity | What a check reads |
|---|---|---|
| Rated wall or floor | IfcWall, IfcSlab with FireRating | Which elements are fire barriers |
| Opening in the barrier | IfcOpeningElement via IfcRelVoidsElement | Where something passes through |
| Duct or pipe | IfcFlowSegment | What crosses the barrier and its size |
| Fire damper | IfcDamper with predefined type FIREDAMPER or FIRESMOKEDAMPER | Whether a damper sits at the boundary |
| Cable tray | IfcCableCarrierSegment | Trays crossing rated elements |
Why models fail this check
- Duct crosses a rated wall with no damper modelled at the boundary.
- Damper modelled, but placed away from the wall so it does not protect the opening.
- Opening not modelled, so the check cannot see the penetration at all.
- Architectural and MEP models not federated, so the crossing is never seen in one place.
- Pipe or tray penetrations with no fire-stop callout.
What a Verify AI finding looks like
Example finding: duct through fire wall without damper
Severity: MEDIUM
Element: IfcFlowSegment crossing a fire-rated IfcWall
Location: Level 3, plant room wall
Detected: no fire damper at the penetration
Requirement: protected penetration through a rated compartment wall
Action: add a fire damper at the boundary and specify a tested fire-stop
This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.
How to prepare your model
- Federate the models: review architectural and MEP together so crossings are visible.
- Model the openings: include openings where services cross rated elements.
- Place dampers at the barrier: position fire dampers at the wall or floor line.
- Mark fire-stops: add callouts or properties for fire-stop systems.
- Keep evidence: file the test certificates for the systems you specify.
Frequently asked questions
What is service penetration fire safety?
It is the protection of openings where ducts, pipes and cables pass through fire-rated walls and floors, so fire and smoke do not travel through them into the next compartment.
Is a fire damper always required?
Not in every case. Requirements depend on the code edition, the duct, and the compartment design, and some designs use other protection. The check reports the requirement it applied and where the clause is.
What is IS 12458:2019?
The Indian Standard referenced by NBCS 2026 guidance for tested fire-stop systems in service penetrations through fire-rated compartment walls.