Service penetrations and fire-stopping, found before the site does.

Check ducts, pipes and cable trays that cross fire-rated walls and floors in your BIM model: missing fire dampers, unsealed openings and fire-stop requirements such as IS 12458:2019.

What is service penetration fire-stopping check?

A service penetration check finds every place a duct, pipe or cable tray crosses a fire-rated wall or floor, and confirms the opening is protected: a fire damper in a duct, a tested fire-stop around a pipe or tray. These are the places fire and smoke spread between compartments, and they sit exactly where the architectural and MEP models meet, which is why they are easy to miss.

What the code asks for

The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.

How it shows up in an IFC model

ItemIFC entityWhat a check reads
Rated wall or floorIfcWall, IfcSlab with FireRatingWhich elements are fire barriers
Opening in the barrierIfcOpeningElement via IfcRelVoidsElementWhere something passes through
Duct or pipeIfcFlowSegmentWhat crosses the barrier and its size
Fire damperIfcDamper with predefined type FIREDAMPER or FIRESMOKEDAMPERWhether a damper sits at the boundary
Cable trayIfcCableCarrierSegmentTrays crossing rated elements

Why models fail this check

What a Verify AI finding looks like

Example finding: duct through fire wall without damper

Severity: MEDIUM

Element: IfcFlowSegment crossing a fire-rated IfcWall

Location: Level 3, plant room wall

Detected: no fire damper at the penetration

Requirement: protected penetration through a rated compartment wall

Action: add a fire damper at the boundary and specify a tested fire-stop

This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.

How to prepare your model

  1. Federate the models: review architectural and MEP together so crossings are visible.
  2. Model the openings: include openings where services cross rated elements.
  3. Place dampers at the barrier: position fire dampers at the wall or floor line.
  4. Mark fire-stops: add callouts or properties for fire-stop systems.
  5. Keep evidence: file the test certificates for the systems you specify.

Frequently asked questions

What is service penetration fire safety?

It is the protection of openings where ducts, pipes and cables pass through fire-rated walls and floors, so fire and smoke do not travel through them into the next compartment.

Is a fire damper always required?

Not in every case. Requirements depend on the code edition, the duct, and the compartment design, and some designs use other protection. The check reports the requirement it applied and where the clause is.

What is IS 12458:2019?

The Indian Standard referenced by NBCS 2026 guidance for tested fire-stop systems in service penetrations through fire-rated compartment walls.