Fire wall continuity checking across the whole building.
Fire wall continuity checking finds gaps in compartment walls: walls that stop at a ceiling, openings without rated closures and shafts that are not enclosed to the slab above.
What is fire wall continuity check?
A fire wall is only as good as its weakest point. Fire wall continuity checking follows each rated wall and compartment boundary through the model and flags where it breaks: a wall that stops at a suspended ceiling instead of reaching the slab, a shaft that is not closed at the top, or an opening in the wall with no rated closure.
What the code asks for
- Fire-rated walls and floors are continuous around the compartment they define, up to the underside of the slab above.
- Shafts for services, lifts and ducts are enclosed and rated along their whole height.
- Openings in the barrier (doors, hatches, glazing) have a rating that matches the barrier.
- Ratings are shown on the drawings and carried in the model.
The exact values (ratings, distances, widths, densities) come from the code edition your authority applies, so a check always reports which edition and clause it used.
How it shows up in an IFC model
| Item | IFC entity or property | What a check reads |
|---|---|---|
| Rating of the wall | Pset_WallCommon.FireRating on IfcWall | Which walls are fire barriers |
| Compartment role | Pset_WallCommon.Compartmentation | Whether the wall is designed as a fire compartment boundary |
| Wall extent | Wall geometry and storey height | Whether the wall reaches the slab above |
| Slabs and shafts | IfcSlab, openings in slabs | Vertical continuity and slab openings |
| Openings | IfcOpeningElement, IfcDoor, IfcWindow | Closures in the barrier and their rating |
Why models fail this check
- Walls modelled to the ceiling height, not to the slab, leaving a void above.
- Rated walls that change thickness or type partway along a compartment line.
- Shaft walls missing at plant levels or at the top of the shaft.
- Glazing or openings in a rated wall with no rated assembly.
- Rating missing from some wall types, so a boundary looks like it has a gap.
What a Verify AI finding looks like
Example finding: compartment wall stops at ceiling
Severity: HIGH
Element: IfcWall (FireRating recorded)
Location: Level 4, corridor compartment line
Detected: wall top is below the underside of the slab above
Impact: compartment boundary is not continuous
Action: extend the wall to the slab and fire-stop the head of wall
This is an illustrative example. Every finding is pinned to the plan, names the element, and cites the clause it was checked against. See a full sample report.
How to prepare your model
- Mark the barriers: set FireRating on every wall that forms a compartment boundary.
- Extend to the slab: model rated walls up to the structure above.
- Close the shafts: check shaft walls along their full height.
- Rate the openings: assign ratings to doors and glazing in rated walls.
- Review the plan: compare the model with the fire strategy drawing.
Frequently asked questions
What is fire compartmentation?
Dividing a building into fire-resistant cells so a fire and its smoke stay in one area long enough for people to leave and for firefighters to act.
Why do walls stop at the ceiling in models?
Because walls are often drawn to the finished ceiling height. Rated walls usually need to continue to the slab above, so the model has to show that.
Does the check replace a fire engineer's review?
No. It finds geometric and data gaps quickly. A qualified fire consultant remains responsible for the strategy and the submission.